Item Model Unit
|
DZL1-0.7-AIIDZL1-1.0-AII
|
DZL2-1.0-AII
|
DZL2-1.25-AII
|
DZL4-1.25-AII
|
DZL4-1.6-AII
|
DZL6-1.25-AII
|
DZL6-1.6-AII
|
DZL10-1.6-AII
|
DZL15-1.6-AII
|
||
Rated Steam Capacity
|
t/h
|
1
|
2
|
2
|
4
|
4
|
6
|
6
|
10
|
15
|
|
Rated Working Pressure
|
Mpa
|
0.7 / 1.0
|
1
|
1.25
|
1.25
|
1.6
|
1.25
|
1.6
|
1.6
|
1.6
|
|
Rated Steam Temperature
|
℃
|
174 / 184
|
184
|
194
|
194
|
204
|
194
|
204
|
204
|
204
|
|
Imput Water Temperature
|
℃
|
20
|
20
|
20
|
20
|
20
|
20
|
20
|
105
|
105
|
|
Heating Area
|
㎡
|
57.47
|
89.4
|
94.8
|
124.9
|
130
|
216.4
|
227.2
|
352.2
|
484
|
|
Fuel
|
Coal
|
Soft Coal II
|
Soft Coal II
|
Soft Coal II
|
Soft Coal II
|
Soft Coal II
|
Soft Coal II
|
Soft Coal II
|
Soft Coal II
|
Soft Coal II
|
|
Consumption
|
Kg/h
|
170
|
330
|
330
|
656
|
656
|
980
|
980
|
1620
|
1620
|
|
Thermal Efficiency
|
%
|
80
|
80
|
80
|
80
|
80
|
81
|
81
|
81
|
81
|
Item Model Unit
|
DZL0.7-0.7-95/70-AII
|
DZL1.4-0.7-95/70-AII
|
DZL2.8-0.7-95/70-AII
|
DZL4.2-1.0-115/70-AII
|
|
Rated Steam Capacity
|
MW
|
0.7
|
1.4
|
2.8
|
4.2
|
Rated Working Pressure
|
Mpa
|
0.7
|
0.7
|
0.7
|
1
|
Outlet water Temperature
|
℃
|
95
|
95
|
95
|
115
|
Water return Temperature
|
℃
|
70
|
70
|
70
|
70
|
Heating Efficiency
|
%
|
80%
|
80%
|
80%
|
80%
|
Area of Stoker
|
㎡
|
1.8
|
2.7
|
5.5
|
9.5
|
Heat Area
|
㎡
|
40.2
|
73.7
|
156.5
|
310.5
|
Fuel
|
|
Coal available
|
II type bitumite, low heat capability 17700-21000KJ/KG
|
||
Fuel Consumption
|
Kg/h
|
263.17
|
391.763
|
767.5
|
900
|