Model No
|
GLTS-021-65-LW
|
GLTS-041-65-LW
|
|||
Testing method
|
Two-liquid bath system with specimen basket transfer
|
||||
Test zone size W*H*D(mm)
|
200*350*300*2Bath
|
260*350*450*2Bath
|
|||
Test zone size W*H*D(mm)
|
1140*1785*1240mm
|
1200*1785*1320mm
|
|||
Performance
|
Hot bath
|
Preheat temperature range
|
+80℃~+200℃
|
||
Temperature fluctuation
|
±2℃
|
||||
Temp.heat-up rate
|
Ambient temp.to+150℃ within 90min
|
||||
Temp.pull-down rate
|
+150℃ to +60℃ within 60min
|
||||
Cold bath
|
Precool temperature range
|
-60℃~0
|
|||
Temperature fluctuation
|
±2℃
|
||||
Temp.heat-up rate
|
-65℃ to 0 within 60min
|
||||
Temp.pull-down rate
|
Ambient temp.to -65℃ within 120min
|
||||
System
|
Circulation system
|
Sirocco fan
|
|||
Heating system
|
SUS#304 stainless steel high-speed heater
|
||||
Cooling system
|
Imported compressor,Tecumseh compressor(or Bizer Compressor),finned type evaporator,air(Water)-cooling condenser
|
||||
Controller
|
TEMI990,8226,8227,8229
|
||||
Thermal shock range
|
-65.00℃~00.00℃/+600.00℃~150.00℃
|
||||
Testing time
|
5min
|
5min
|
|||
Transfer time
|
Approximately 10 seconds
|
||||
Temp.resolution
|
0.1℃ / 1 min
|
||||
Specimen Basket size(mm)
|
100*180*200mm
|
160*180*350mm
|
|||
Specimen basket load capacity
|
1C 2Kg
|
1C 5kg
|
|||
Controller
|
Color TFT LCD panel(6.5inch)
|
||||
Power supply
|