Xenon Test Chamber/weather ometer

본문 바로가기


Home > Product > Xenon Test Chamber/weather ometer
Product
Xenon Test Chamber/weather ometer
Posting date : Mar 07, 2019
Membership
Free Member Scince Jul 27, 2017
FOB Price
1 usd
Min. Order Quantity
1 set
Supply Abillity
5 sets
Port
shanghai
Payment Terms
tt
Package
Packed by solid wooden case;
Keyword :
Category
Contact
ann
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
qinsun
HS-CODE
-
Package & Delivery Lead Time
Package
Packed by solid wooden case;
Delivery Lead Time
2 weeks
Detailed Description
Weather-Ometer and Fade-Ometer tester adopts water-cooled xenon lamp. This instrument using argon arc lamp simulation control ideal natural climate and solar and other experimental conditions to to test the color and performance of textile dyes. It can also test the material Anti-aging properties, which can ensure good reproducibility and reproducibility on the basis of accurate test product life. Besides, it is widely used in plastics, paint coating, ink, packaging, automotive materials, photochemical materials, pigment dyes and textiles and other industries. The equipment has been certified by several international standards organizations. ApplicationsWeather-Ometer and Fade-Ometer with their advanced digital control systems, represent monumental achievements in applying digital and optical technologies in easy-to-use laboratory weathering instruments. The Series is approved by many OEMs in the textiles, paints & coatings and plastics industries as the exclusive platform to deliver accurate, reproducible and repeatable results for predicting service life. The Series has been certified CE, UL, CSA, ISO and EN compliant
Features◆ Xenon Lamp Cooling System-The Series is equipped with a new,ground-breaking xenon lamp cooling system that dramatically reduces the amount of cooling water used.◆ Rotating Sample Rack-Rotating rack delivers the best exposure uniformity  ◆ Control system - Enhanced control system can handle complex custom programs and simple preprogrammed test, and simple operation page icon is clear and easy to understand ; Irradiation, temperature, humidity programmable step by step change, to meet the various user test requirements.◆ Intelligent and friendly operating system - intuitive LCD touch interface, full-featured, a variety of languages can be selected; water purity indicator can monitor the input water quality; SmartLight MonitorTM ensures that the lamp is installed correctly.◆ Irradiance closed-loop monitoring and automatic adjustment, can be calibrated by the irradiance calibration device on a regular basis. Radiation calibration device should be CNAS / A2LA / JAB and other international mutual recognition agency certificate. The calibration mechanism of the calibration device shall be certified by ISO 17025. StandardsISO 105-B04 Textiles - Tests for colour fastness - Part B04: Colour fastness to weathering: Xenon arc testISO 105-B06 Textiles - Tests for colour fastness - Part B06: Colour fastness and ageing to artificial light at high temperatures: Xenon arc fading lamp testISO 105-B10 new standardTextiles - Tests for colour fastness - Part B10: Artificial weathering - Exposure to filtered xenon-arc radiationISO 12040 Graphic technology - Prints and printing inks - Assessment of light fastness using filtered xenon arc lightISO 16474-2 Paints and varnishes - Methods of exposure to laboratory light sources - Part 2: Xenon-arc lampsISO 3917 Road vehicles - Safety glazing materials - Test methods for resistance to radiation, high temperature, humidity, fire and simulated weatheringISO 4892-1 Plastics - Methods of exposure to laboratory light sources - Part 1: General guidanceISO 4892-2 Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc sourcesTechnical Parameters 
Items Parameters
Light source 4500 W water-cooled xenon arc lamp
Xenon lamp life More than 1000 hours. The spectral energy distribution curve was stable after 300 hours
Filter  Internal and external filters (daylight filter, window glass filter, UV extension filter) can be replaceable
Irradiance control 340/420 or 300-400nm select single point automatic control, optional second point monitoring
Lighting monitoring Intelligent light monitoring
Relative humidity control Automatic
Humidity range Drying cycle Humidity: 20-80 ± 5% RH, wetting cycle Humidity: 95 ± 5%
Temperature control Automatic   Test chamber temperature control: 20-65 ± 2 ℃
Temperature Black Standard Temperature (BST) :50~100±2℃ BlackPanel Temperature (BPT) :45~90±2℃
Simultaneous control BPT or BST and chamber temperature Standard
BPT/BST double control Optional
Specimen frame type Monolayer
Exposure test area 2188cm2(339in2)
Power supply 400/230V, 3phase, 4 wire, 50Hz, 38 A
HVAC-MJ/h (BTU/h) (maximum) 26.06MJ/h (24703BTU/h, 275CFM)
Compressed air 0.11m3/min (Max 4CFM), @552kPa, (80psi)
Water flow Pressure: 38-345kPa (20-50psi)
Humidification: deionized water 0.12l / min
Sample spray: deionized water 0.07l / min
Sample rack spray: deionized water 0.07l / min
Dimension (L x W x H):95cm x 84cm x 183cm
Base 115cm x 240cm
Weight 404kg (890lb)
Daylight filter and UV extension filter @ 340 setting range ≥0.51W/m
Window glass filter @ 420nm setting range ≥1.1W/m
Irradiance control deviation ±0.01W/m2
@Tuv (300nm-400nm) between the average irradiance More than 120W / m2The irradiance E at any point on the surface of the specimen does not exceed ± 10% of the average of the irradiance on the entire surface.
Radiation exposure area ≥3000cm2  Also accommodate specimen number ≥50
Specimen size Between 50*100mm and 70*150mm
Test area height (flat) ≥30cm
Single automatic cycle test time setting upper limit ≥2000 hours

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top