1000Ah / 5hrs 36V Forklift Traction Battery Durable Environmentally Friendly

본문 바로가기


Home > Product > 1000Ah / 5hrs 36V Forklift Traction Battery Durable Environmentally Friendly
Product
1000Ah / 5hrs 36V Forklift Traction Battery Durable Environmentally Fr...
Posting date : Aug 18, 2017
Membership
Free Member Scince Aug 11, 2017
FOB Price
Negotiable
Port
China
Payment Terms
L/C, T/T, W
Package
Shrink Wrapped, Steel Tray, Wooden case
Keyword :
Category
Contact
LAKER
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
MYING
Model Number
36V 1000Ah/5hrs
HS-CODE
85-
Package & Delivery Lead Time
Package
Shrink Wrapped, Steel Tray, Wooden case
Delivery Lead Time
25 days After Order Confirmation and Deposit
Detailed Description
1000Ah / 5hrs 36V Forklift Traction Battery Durable Environmentally Friendly - - - - Type | Forklift Battery | Application | Electric Forklift Truck | Standard | BS standard | Width of cell | 158mm | Technology | Tubular Positive Plates | Model | 36V 10DB1000 | Cell Quantities | 18 cells | Cell Voltage | 2V | Connection Type | Flexible connection | Steel Tray Size | Standard or Customized | - - - - Product Catalogs --- BS standard - - - - Type | 5hr. Capacity(Ah) | Overall Dimension (mm) | Wet Weight (kg) | Poles | Cell Volt (v) | 2DB200 | 200 | 45x158x622x653 | 13 | 2 | 2 | 3DB300 | 300 | 61x158x622x653 | 18.1 | 2 | 2 | 4DB400 | 400 | 77x158x622x653 | 23.3 | 2 | 2 | 5DB500 | 500 | 93x158x622x653 | 28.4 | 2 or 4 | 2 | 6DB600 | 600 | 109x158x622x653 | 33.6 | 2 or 4 | 2 | 7DB700 | 700 | 125x158x622x653 | 38.8 | 2 or 4 | 2 | 8DB800 | 800 | 141x158x622x653 | 44.5 | 4 | 2 | 9DB900 | 900 | 157x158x622x653 | 49.6 | 4 | 2 | - - - - Product Strength 1. High quality flooded lead acid battery 2. >= 1500 times cycle life. 3. High performance tubular positive plates 4. Meet IEC 60254 standard. 5. CE,ISO9001 and ISO14001. 6. Lower distilled water consumption 7. Environmental and healthy 8. Nice design and good quality 9. Easy to use and durable 10. Low current recharge 11. Competitive price 12. Wooden case packaging 13. Automatic watering syste and Argitation system. 14. Larger and thicker plate means less internal corrosion Trouble Shooting There are many reasons of the cells troubleshooting, except for the quantity and the storage, operating wrongly and unmerited maintenances are also one of the most important reasons. If you find troubleshooting, analyze the reasons in time and take effective measures to eliminate it. The features of the familiar troubleshooting and the reason and the methods of checking and repairing are as following: 1. Internal short-circuit 1.1 Symptoms The charge voltage is always lower than normal; the discharge capacity is lower than normal; the discharge voltage quickly reduced to the final voltage; the voltage and the specific gravity raise slowly, and less or without gassing at the end of charge; the temperature of the electrolyte is high and raise faster during charge; the self-discharge is serious. 1.2 Probable causes There are many reasons of short-circuit: conducting materials enter the cells connecting the positive and negative plates; the separator is damaged; the plates give birth to the lead bulb and store at the ear of the plates making short-circuit; the active materials are expanded or shed, the sediment touch the bottom of the plates leading short-circuit. 1.3 Possible remedy First check if there are conducting materials entering the cells, if there are, remove the conductors. Remove the plates group checking if the lead-bulb expend leading short-circuit, if it is, remove the lead-bulb and change the electrolyte. If the separator is damaged, separate the plates group and find the damage one and change a new one. 2. The reversible vitriolic salt of the plates 2.1 Features The discharge capacity is reduced and the specific gravity is lower than normal; during charge, the initial and the final voltage is higher than normal; the gassing appears too early and the temperature of the electrolyte raise fast and easy to exceed 55 ; voltage reduces too fast when discharge and reduces to the final voltage too early. 2.2 The reasons of troubleshooting The cells are often weakly charged or not equalizing charged in time or often over-discharging or small-current discharging, in the station of half-discharging or discharging for a long time, or the level of the electrolyte is too low and some other reasons make the vitriolic lead in the positive and negative plates hard to transform into the active materials. 2.3 The ways to solve the problem For the cells of plates with vitriolic salt, if it is not serious, you can revert by proper over-charging; for the serious ones, you can charge with small current; for the most serious ones, you can deal with them by using hydropath. In the sake of protecting from it, you should operate according to the service manual and take equalizing charge in time.

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top