CLHS Series Vertical Domestic Oil Fired Atmospheric Pressure Hot Water Boiler

본문 바로가기


Home > Product > CLHS Series Vertical Domestic Oil Fired Atmospheric Pressure Hot Water Boiler
Product
CLHS Series Vertical Domestic Oil Fired Atmospheric Pressure Hot Water...
Posting date : Jan 18, 2017
Membership
Free Member Scince Jan 07, 2017
FOB Price
10.00
Min. Order Quantity
1
Supply Abillity
normal
Port
all
Payment Terms
all
Package
unit
Keyword :
Category
Contact
BaoXuhua
          0 likes     
Product Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
CLHS Series Vertical Domestic Oil Fired Atmospheric Pressure Hot Water Boiler,Oil Hot Water Boiler
HS-CODE
-
Package & Delivery Lead Time
Package
unit
Detailed Description
VERTICAL OIL HOT WATER BOILER SpecificationTypeCLHS0.06-85/60-Y.QCLHS0.12-85/60-Y.QCLHS0.17-85/60-Y.QCLHS0.23-85/60-Y.QCLHS0.35-85/60-Y.QCLHS0.47-85/60-Y.QCLHS0.58-85/60-Y.QProjectUnitRated thermal powerMW0.060.120.170.230.350.470.58Total heat capacity 104kcal5101520304050Rated working pressureMPaAtmospheric pressure                                      Fuel    consumptionLight diesel oilkg/h5.410.816.221.632.543.254Natural gasNm3/h5.811.717.523.43546.858.5LPGNm3/h2.557.510152025C.G.Nm3/h14.228.342.556.685113.2141.5vertical Oil Hot Water Boiler Dimension Water inlet diameterDN506565656580100Water outlet diameterDN506565656580100Blowoff  valve diameterDN25252525254040VoltageV220220220220380380380      Overall sizeLengthmm80098011501250150015501600Widthmm7008509001000120012501450Heightmm1300165018001950200021002500Weightkg2704104505208309801500Wilford could provide customized products with specific power supply in the world.VERTICAL OIL HOT WATER BOILER PRODUCT DESCRIPTIONsmall size ,vertical structure, make full usage of room space .High thermal resistance of insulation materials, minimum boiler heat losses.Imported burner, pressure spray, complete burning, low noise ,almost no pollution, protect environment .Pressure connecting structure, safe, reliable, long service life.Fully automatic control, easily operation.Multiple chain protection, self test such as over temperature /water shortage /overload /ignition failure, abnormal flame out.Oil(gas)Hot Water BoilerSpecificationTypeCLHS0.06-85/60-Y.QCLHS0.12-85/60-Y.QCLHS0.17-85/60-Y.QCLHS0.23-85/60-Y.QCLHS0.35-85/60-Y.QCLHS0.47-85/60-Y.QCLHS0.58-85/60-Y.QCWNS0.7-85/60-Y.QCWNS1.05-85/60-Y.QCWNS1.4-85/60-Y.QCWNS1.75-85/60-Y.QCWNS2.1-85/60-Y.QCWNS2.8-85/60-Y.QProjectUnitRated thermal powerMW0.060.120.170.230.350.470.580.71.051.41.752.12.8Total heat capacity  104kcal51015203040506090120150180240Rated working pressureMPa                                                   Fuel  consumptionLight diesel oilkg/h5.410.816.221.632.543.2546597.5130162195260Natural gasNm3/h5.811.717.523.43546.858.570105140175210280LPGNm3/h2.557.5101520253045607590120 City  gas Nm3/h14.228.342.556.685113.2141.5170255340425510680 Dimension               Water inlet    diameter DN506565656580100100125150150200200Water outlet diameter DN506565656580100100125150150200200Blowoff  valve diameter DN25252525254040505050506565VoltageV220220220220380380380380380380380380380Overall sizeLengthmm80098011501250150015501600302032303650410045505600Widthmm7008509001000120012501450170017501820189019302000Heightmm1300165018001950200021002500188019602050210021502270Weightkg2704104505208309801500245027803500386045206300Wilford could provide customized products with specific power supply in the world.Product description CWNS series hot water boiler is three-pass all wet back shell type structure.Main body includs boiler shell, furnace, boiler smoke chamber and convection bank. convection smoke tube is made by threaded pipes,  enhance heat transfer.Big furnace, high radiation area, three return design, full air combustion, good usage of heating surface.Smoke tubes add disturb fins inside, increasing heating area, self-clean for dust ,improving heat transfer effectiveness. Using high thermal resistance of insulation materials boiler heat minimum losses.More than 90% thermal efficiency. Intelligent,fully automatic control, over-temperature stand by. Anti-freezing in cold winter night,automatic adjust heating supply temperature base on out door temperature ,which , maximum achieve energy saving .Imported burner ,pressure spray ,complete burning ,low noise .Reduced combustion intensity ,decrease dust emissions ,output of harmful gases such as NOx emissions reduced to the minimum,  meet serious environmental requirements.Pressure connecting structure, safe, reliable, long service life. Multiple chain protection and self-test such as -over temperature ,water shortage ,overload, ignition failure, abnormal flameout, gas leakage. Expansion  water tank directly connect to atmosphere,no potential safety problems under  atmospheric pressure operation. url:http://www.weifu-boiler.com

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2026 ECROBOT.COM. All rights reserved.
Top