Global Trade leader ecrobot

본문 바로가기


Home > Selling Leads > search Transformer
Selling Leads 1,056 Result
Cable test system | Transformers and Cables Test Van Laboratories | ET...
Dec 14 2017
Cables Test Van Laboratories ETL-8V is a modular diagnostic and test equipment, which is designed for testing and fault location of both LV and MV cables. The key parameters are de…
HS-CODE : 9030-33
KharkovEnergoPribor Ltd.
Ukraine, CIS [UA]
Scince 2004
Free Member
Cable test system | Transformers and Cables Test Van | ETL-80V
Dec 14 2017
Cable test system ETL-80V is a modular diagnostic and test equipment, which is designed for testing and fault location of both LV and MV cables. The key parameters are designed fle…
HS-CODE : 9030-33
KharkovEnergoPribor Ltd.
Ukraine, CIS [UA]
Scince 2004
Free Member
Cable test van | Transformers and Cables Test Van Laboratories | ETL-4...
Dec 14 2017
Cable test van ETL-40V is a modular diagnostic and test equipment, which is designed for testing and fault location of both LV and MV cables. The key parameters are designed flexib…
HS-CODE : 9030-33
KharkovEnergoPribor Ltd.
Ukraine, CIS [UA]
Scince 2004
Free Member
Transformer Long Neck big size Car Bracket Car Phone Mount Holder
Aug 25 2016
Transformer Long Neck big size Car Bracket2in1 for dashboard + windshield usingWith PU sucking cupFit for phone, GPS within 50mm - 105mm and 3inch - 7inchFor iphone6/plus/5s/5c, Samsung Galaxy s6/s5 e…
HS-CODE : 3926-90
SHENZHEN REDLP ELECTRONI...
China [CN]
Scince 2008
Free Member
ZC-203B Transformer Ratio Tester
Jun 27 2016
Product Introduction This product applies to test the transformer ratio(transformer testing), group and polarity of the single/three phase transformer and voltage transformer. It is small volume,…
HS-CODE : 8543-90
KV Grid Tester Co.,Ltd
China [CN]
Scince 0
Free Member
gsm gprs electricity transformer anti-theft system S251
May 30 2016
Model: S251 Name: GSM 3G Power Distribution Monitoring System The GSM 3G Power Distribution Monitoring System is not only a smart power meter for measuring the power distributor voltage, curre…
HS-CODE : 9030-39
King Pigeon GSM 3G Telem...
China [CN]
Scince 2005
Free Member
customized linear current transformer
May 09 2016
error range: accuracy class Current ratio error(%) phase error Rated current percentage value Rated current percenta…
HS-CODE : 8543-30
Zhejiang Enhong Electron...
China [CN]
Scince 2015
Free Member
customized anti-DC component current transformer
May 09 2016
error range: accuracy class Current ratio error(%)  phase error Rated current percentage value Rated cur…
HS-CODE : 8543-30
Zhejiang Enhong Electron...
China [CN]
Scince 2015
Free Member
customized precision current transformer
May 09 2016
CTG series are precision current transformers, the precision grade is 0.1 class,they are widely used in grid electricity measurement meter and intelligent power system; error range: …
HS-CODE : 8543-30
Zhejiang Enhong Electron...
China [CN]
Scince 2015
Free Member
customized high-precision current transformer
May 09 2016
CTS series are high-precision current transformers, they are manufactured strictly under the instruction of "a current transformer" patent technology of patent number CN102709042B …
HS-CODE : 8543-30
Zhejiang Enhong Electron...
China [CN]
Scince 2015
Free Member
Single Stage High Efficiency Vacuum Transformer Oil Purifier
Apr 27 2016
Application:  This machine is special for purifying various of insulating oils including unqualified transformer oil, mutual inductor oil and circuit breaker oil etc. It is widely applied to…
HS-CODE : -
Category :
zhongneng Oil Purifier M...
China [CN]
Scince 2004
Free Member
Precision current transformer magnetic cores
May 09 2016
The Bs of Nanocrystalline alloy is between Silicon steel and permalloy. The lower the Bs value, the more beneficial to reduce instrument security factor. When the system fails and generates a large …
HS-CODE : 8543-70
Zhejiang Enhong Electron...
China [CN]
Scince 2015
Free Member
Linear current transformer magnetic cores
May 09 2016
In modern measurement filed, linear transformer are widely used especially known as Hall sensor. The advantages of Hall sensor are good output signal and wide testing range etc. , while the drawbacks …
HS-CODE : 8543-70
Zhejiang Enhong Electron...
China [CN]
Scince 2015
Free Member
High frequency transformer nanocrystalline cores
May 09 2016
Transformer is irreplaceable in the power supply system. It has the following main functions: Electrical isolation;To realize the voltage rise or fall by different variety; High power rectifier vice e…
HS-CODE : 8543-70
Zhejiang Enhong Electron...
China [CN]
Scince 2015
Free Member
DC resistance current transformer cores
May 09 2016
When using current transformers, the accuracy of measurement determined by the primary current amplitude error (contrast) and phase error (difference). In medium accuracy without the requirement of DC…
HS-CODE : 8543-70
Zhejiang Enhong Electron...
China [CN]
Scince 2015
Free Member

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top