SZS Double Drums Water Tube Boiler

본문 바로가기


Home > Product > SZS Double Drums Water Tube Boiler
Selling leads
SZS Double Drums Water Tube Boiler
Posting date : Oct 13, 2018
Membership
Free Member Scince Jan 08, 2018
FOB Price
-
Min. Order Quantity
-
Supply Abillity
-
Port
-
Payment Terms
-
Package
-
Keyword :
Category
Contact
Carol Zong
Selling Leads Detail
Company Info
 
Quick Detail
Place of Origin
China [CN]
Brand Name
-
HS-CODE
-
Package & Delivery Lead Time
Package
-
Detailed Description
Capacity: 6t/h-20t/h   4.2mw/h - 14mw/h
Pressure: 0.7Mpa-1.6Mpa
Fuel: Natural gas, Lpg, Light oil, Diesel, Heavy oil, Dual fuels. 
Oil/Gas Fired Boiler Introduction 
SZS series boiler body is double-drum, horizontal with D-type combustion chamber, the furnace is on the right, and the convection tubes on the left, movable supports in the midst and both sides of the furnace are mixed into the bottom plate of the boiler body, making sure that the boiler is expanding toward both sides in the whole. The furnace has narrow pitch pipe membrane water cooling walls in the surrounding, the membrane water cooling wall on the left of the furnace is completely sealed from the convection tubes. Behind the convection tubes is the sparse staggered structure, at the front is the aligned structure. The smoke from the burning in the combustion chamber leaves from smoke output at the back part of the furnace, enters into the burnout chamber and convection tubes, and then into finned tube economizer and condenser, and finally into the chimney by the flue and finally into the air.  
Oil & Gas Fired Boiler, Vertical Boiler, Double Drums Water Tube Boiler, Vertical Boiler For Sale Factory.
Advantages
1. Manhole, inspection door
Manholes are set at the front and back of the furnace as well as the above and bottom part, the inspection door is set at the hind part of the boiler, easy to open from check and cleaning.
2. Reliable water cycling
The high temperature part of the boiler body employs forced circulation, ensuring that all heating surfaces can be cooled properly and vaporization is prevented.
3. Membrane structure
◎The full membrane wall structure type I layout
◎Steam drum, water drum convection bank from convection heating surface, and ensure boiler as a whole expand to both ends.
◎Combustion chamber using narrow spacing membrane water wall, with good air tightness, reducing heat losing, improving the thermal efficiency of the boiler.
◎The back of the convection bank area is sparse shift structure.The front of the convection bank area is sequnce structure.
◎Front and back wall of boiler body all using membrane structure, greatly increase the service life of the front and back wall, ensure the service life of the front and back wall more than 20 years.
◎Membrane wall on both sides of boiler furnace and the sealing between the drum all use comb board, to eliminate the used refractory concrete sealing result in condensate and gas leak problem.
4. Furnace insulation
Using high quality aluminum silicate fiber, then fire clay insulation, furnace temperature was controlled below 45°,effective control the heat loss.
5. Combustion chamber
Due to the combustion chamber adopts full membrane water wall structure, and by the micro positive pressure combustion, so without smoke issues. Working environment pollution-free.
6. Installation devices
Boiler is decorated with explosion door and flame detector, safe and reliable operation.
YongXing manufacture Oil & Gas Fired Boiler, Biomass Fired Boiler, Thermal Oil Boiler, Pressure Vessels, Electrical Steam Boiler, Hot Air Boiler, Coal Fired Boiler etc. We are the national A- class boiler manufacturer
 
Steam boiler
Item           Model          Unit   
SZS6-1.25-Q.Y  SZS6-1.6-Q.Y  SZS6-2.5-Q.Y
SZS10-1.25-Q.Y  SZS10-1.6-Q.Y  SZS10-2.5-Q.Y
SZS20-1.25-Q.Y  SZS20-1.6-Q.Y  SZS20-2.5-Q.Y
SZS30-1.25-Q.Y  SZS30-1.6-Q.Y  SZS30-2.5-Q.Y
SZS40-1.25-Q.Y  SZS40-1.6-Q.Y  SZS40-2.5-Q.Y
SZS50-1.25-Q.Y  SZS50-1.6-Q.Y  SZS50-2.5-Q.Y
Rated evaporation capacity
t/h
6
10
20
30
40
50
Rated working pressure 
Mpa
1.25/1.6/2.5
1.25/1.6/2.5
1.25/1.6/2.5
1.25/1.6/2.5
1.25/1.6/2.5
1.25/1.6/2.5
Rated steam temperature
194/204/225
194/204/225
194/204/225
194/204/225
194/204/225
194/204/225
Designed heat efficiency
%
>98
>98
>98
>98
>98
>98
Available fuel
 
Natural gas/biogas/coke gas/light oil/methanol/biodiesel etc
Fuel consumption 
Light oil
kg/h
372
620
1240
1860
2480
3100
Natural gas
M³/h
432
720
1440
2160
2880
3600
 
Hot water boiler with pressure
Item                                    Model                                               Unit 
SZS7-1.0/115/70-Q.Y
SZS10.5-1.0/115/70-Q.Y
SZS14-1.25/115/70-Q.Y
SZS17.5-1.25/115/70-Q.Y
SZS21-1.25/130/70-Q.Y
Rated Thermal Power
MW
7
10.5
14
17.5
21
Rated Outlet Water Pressure
Mpa
1.0
1.0
1.25
1.25
1.25
Rated Outlet Water Temperature
95
95
95
115
115
Rated Return Water Temperature
70
70
70
70
70
Thermal Efficiency (Oil/Gas)
%
93.0891.56
91.87
92.713
93.21
91.2
Water Volume
2.6
3.3
6
9
11.6
Funel Temperature (Oil/Gas)
119.68118.15
143.88122.38
127.81
116.3
160
Fuel Consumption (Oil/Gas)
Kgm³/h
69.1681.55
155.82155.82
253.78301
378.65449
644.99764.99

ECROBOT CO., Ltd, Business Registration Number : 220-88-71747, CEO J.W.Park, TEL : +82-2-552-7676, E-mail : E-mail : Contact us
Address : (Hwanghwa B/D 11F, Yeoksam-dong)320, Gangnam-daero, Gangnam-gu, Seoul, South Korea
About Us Privacy Policy Terms of use Copyright © 2000-2024 ECROBOT.COM. All rights reserved.
Top